Second Order Crossover Calculator
What this calculator measures
Calculate individual components of a defined ideal second-order LC section driven by a zero-resistance source into a resistive driver model.
Inputs and units
Keep all entries on the measurement boundary and unit convention stated below. Example values are editable calculation inputs, not specifications for your equipment or a particular production job.
| Input | Example value or available basis |
|---|---|
| Natural Electrical Corner (Hz) | 2500 |
| Resistive Driver Model (ohms) | 8 |
| Electrical alignment | Second-order Butterworth: Q = 1/sqrt(2); Second-order Linkwitz-Riley: Q = 0.5 |
| Section and component | Low-pass series L (mH); Low-pass shunt C across load (microfarads); High-pass series C (microfarads); High-pass shunt L across load (mH) |
Calculation method
Calculate individual components of a defined ideal second-order LC section driven by a zero-resistance source into a resistive driver model.
For low-pass series L and shunt C across R, L=R/(omega Q) and C=Q/(omega R). For high-pass series C and shunt L across R, the component magnitudes remain C=Q/(omega R) and L=R/(omega Q), but their circuit positions change. Here omega=2 pi f.
Worked example
At 2500 Hz, R=8 ohms and Butterworth Q=1/sqrt(2), L is approximately 0.720253 mH and C approximately 5.626977 microfarads. The low-pass uses series L then C across R; the high-pass uses series C then L across R.
How to use the result
Select the output quantity you need, enter compatible values, and compare the result with the independently worked example. Where the form offers several output choices, read the units in that choice; different physical quantities must not be combined into one total.
Limits and checks
The ideal response is -3.0103 dB at the natural corner for Butterworth Q and -6.0206 dB for LR2 Q=0.5. Pair summation also depends on polarity, phase and real acoustic response.
Real driver impedance, winding resistance, component tolerance and source impedance alter the result. These are defined ideal sections, not guaranteed acoustic alignments.
An undefined or out-of-domain combination produces a calculation-failure message. Check the positive denominators, stated input ranges, and any required matching basis before changing the calculation inputs.