Crossover Frequency Calculator

Crossover Frequency Calculator

Calculate an ideal first-order electrical corner from a series capacitor or series inductor feeding an explicitly resistive load.
Ideal first-order electrical corner:
Support this tool
Buy us a coffee
If this Crossover Frequency Calculator helped you, you can support the site with a small donation. It keeps the tools on the site free and supports ongoing improvements.
Buy us a coffee
Secure donation via Gumroad

What this calculator measures

Calculate an ideal first-order electrical corner from a series capacitor or series inductor feeding an explicitly resistive load.

Inputs and units

Keep all entries on the measurement boundary and unit convention stated below. Example values are editable calculation inputs, not specifications for your equipment or a particular production job.

Input Example value or available basis
Resistive Driver Model (ohms) 8
Defined first-order section Series capacitor high-pass; Series inductor low-pass
Series Capacitance for High-Pass Choice (microfarads) 10
Series Inductance for Low-Pass Choice (mH) 0.5

Calculation method

Calculate a first-order high-pass from a series capacitor feeding a resistive load, or a low-pass from a series inductor feeding a resistive load. Output is voltage across the load from an ideal low-impedance source.

For the high-pass section, fc = 1 / (2 pi R C), with capacitance converted from microfarads to farads. For the low-pass section, fc = R / (2 pi L), with inductance converted from millihenries to henries. At fc, amplitude magnitude is 1 / sqrt(2).

Worked example

An 8-ohm model with a 10-microfarad series capacitor has an ideal corner of 1989.436789 Hz. An 8-ohm model with a 0.5 mH series inductor has an ideal corner of 2546.479089 Hz.

How to use the result

Select the output quantity you need, enter compatible values, and compare the result with the independently worked example. Where the form offers several output choices, read the units in that choice; different physical quantities must not be combined into one total.

Limits and checks

Only isolated ideal first-order electrical sections are calculated. Real impedance, additional networks, losses, and driver acoustic response require complete simulation and measurement.

The result does not choose a suitable acoustic handover, certify tweeter protection, or apply to higher-order networks.

An undefined or out-of-domain combination produces a calculation-failure message. Check the positive denominators, stated input ranges, and any required matching basis before changing the calculation inputs.

References and method