Amplifier Clipping Voltage Calculator
What this calculator measures
Estimate an ideal rail-limited peak or sine RMS load-voltage swing for explicitly symmetric rails and a specified output topology.
Inputs and units
Keep all entries on the measurement boundary and unit convention stated below. Example values are editable calculation inputs, not specifications for your equipment or a particular production job.
| Input | Example value or available basis |
|---|---|
| Magnitude of Each Symmetric Rail Relative to Midpoint (V) | 35 |
| Required Rail-to-Output Headroom per Output Half (V) | 3 |
| Defined output topology | Single-ended output referenced to midpoint; Ideal equal opposite-phase bridge outputs |
| Voltage reference | Peak load voltage (V); Unclipped sine RMS load voltage (V RMS) |
Calculation method
Estimate an ideal rail-limited peak or sine RMS load-voltage swing for explicitly symmetric rails and a specified output topology.
Each output half can swing to rail magnitude minus its required output headroom. Single-ended load peak equals that swing; ideal equal opposite-phase bridge load peak is twice it. Divide peak by sqrt(2) for an unclipped sine RMS reference.
Worked example
With symmetric plus/minus 35 V rails and 3 V required headroom per output half, single-ended peak is 32 V and sine RMS is approximately 22.627417 V. Ideal bridge values are 64 V peak and approximately 45.254834 V RMS.
How to use the result
Select the output quantity you need, enter compatible values, and compare the result with the independently worked example. Where the form offers several output choices, read the units in that choice; different physical quantities must not be combined into one total.
Limits and checks
For a single 0-to-70 V supply with midpoint at 35 V, rail magnitude relative to that midpoint is 35 V, not 70 V. The model assumes centered symmetric swing and defined complementary bridge behavior.
Actual clipping depends on load current, supply sag, frequency, thermal/protection behavior, input-stage limits, and the distortion criterion. Headroom must come from applicable data or measurement; this is not a load-independent output guarantee.
An undefined or out-of-domain combination produces a calculation-failure message. Check the positive denominators, stated input ranges, and any required matching basis before changing the calculation inputs.