Speaker Loudness Calculator
What this calculator measures
Estimate free-field point-source SPL from 1 W / 1 m sensitivity, power, distance, and an explicitly uncorrelated equal-source assumption.
Inputs and units
Keep all entries on the measurement boundary and unit convention stated below. Example values are editable calculation inputs, not specifications for your equipment or a particular production job.
| Input | Example value or available basis |
|---|---|
| Sensitivity (dB SPL at 1 W / 1 m) | 88 |
| Electrical Power per Speaker (W) | 10 |
| Reference-to-Listener Distance (m) | 2 |
| Equal Uncorrelated Sources (whole number) | 1 |
| Documented Site Adjustment (dB; normally 0) | 0 |
Calculation method
Estimate ideal free-field point-source SPL from sensitivity at 1 W / 1 m, electrical power per source, distance, equal uncorrelated source count, and an explicit documented adjustment.
SPL = S + 10 log10(P) – 20 log10(d) + 10 log10(N) + G. S is sensitivity in dB SPL at 1 W / 1 m, P is watts per source, d is distance in meters, N is the number of equal uncorrelated sources, and G is a documented adjustment in dB.
Worked example
With sensitivity of 88 dB SPL at 1 W / 1 m, power of 25 W, distance of 2.5 m, one source, and zero adjustment, the estimate is 94.020600 dB SPL. Doubling power to 50 W gives 97.030900 dB SPL, an increase of 3.010300 dB.
How to use the result
Select the output quantity you need, enter compatible values, and compare the result with the independently worked example. Where the form offers several output choices, read the units in that choice; different physical quantities must not be combined into one total.
Limits and checks
Sources are equal and uncorrelated at the stated point. Coherent interference, directivity, arrays, reflections, compression, and air absorption are not modeled.
Sensitivity at 2.83 V requires compatible normalization. Calculated SPL is not listening-exposure guidance or a verified maximum output.