Convert an amplifier voltage-gain ratio to dB with 20 log10(Vout/Vin), using compatible positive RMS voltage measurements. If the ratio is already known, apply the same formula directly; power ratios use a different logarithmic factor.
Open the Amplifier Gain Calculator.
How to Convert Amplifier Gain Ratio to dB
Voltage gain as a linear magnitude ratio is:
Av = output RMS voltage ÷ input RMS voltage
Its decibel form is:
Voltage gain, dB = 20 × log10(Av)
The calculator reports either the linear voltage ratio or its decibel value. Both describe the same selected voltage relationship; a ratio of 20 V/V and approximately 26.02 dB are equivalent expressions.
Use the same voltage units for input and output. Convert millivolts to volts, or volts to millivolts, before dividing if the readings use different units.
Decibels alone express a ratio, not an absolute output voltage. To determine the output amplitude you also need the input amplitude and a valid operating condition in which the amplifier follows that gain.
Calculate a 20-to-1 Voltage Ratio
Suppose a matched measurement gives 1 V RMS at the input and 20 V RMS at the output. Linear voltage gain is 20 ÷ 1 = 20 V/V.
Decibel voltage gain is:
20 log10(20) = approximately 26.02060 dB
Enter input voltage one and output voltage 20 in the calculator. The linear selector should return 20, and the decibel selector should return approximately 26.0206 dB.
If you know only the dimensionless ratio, you can represent it using normalized numbers, such as input one and output 20 for a ratio of 20. That is a conversion representation, not a claim that those voltages were physically measured.
TI’s audio-amplifier gain explanation distinguishes voltage gain, RMS amplitude, and output power in amplifier calculations. Keep those quantities identified rather than substituting one for another because both happen to use a decibel notation.
The example does not establish maximum unclipped output. A real amplifier can cease to follow the linear gain relationship when voltage swing, current, processing, or protection limits are reached.
Use a Reference Table to Check the Conversion
Common voltage-magnitude ratios give:
| Voltage ratio, V/V | Voltage gain or attenuation |
|---|---|
| 0.1 | −20.0000 dB |
| 0.5 | −6.0206 dB |
| 1 | 0 dB |
| 2 | +6.0206 dB |
| 10 | +20.0000 dB |
| 20 | +26.0206 dB |
A ratio above one is positive gain in this convention. A positive ratio below one is attenuation and produces a negative decibel value.
Zero dB means equal input and output voltage magnitudes. It does not mean zero volts, zero power, or no signal. Likewise, negative gain in dB does not mean a negative physical RMS voltage.
Doubling voltage adds approximately 6.0206 dB. Multiplying voltage by ten adds 20 dB. These checks can reveal a mistaken logarithm base or confusion between the voltage and power formulas.
The table concerns magnitude. A polarity inversion or phase shift is separate information and is not represented by changing the sign of an RMS voltage-gain ratio.
Convert Decibels Back to a Voltage Ratio
The inverse relationship is:
Av = 10^(gain in dB ÷ 20)
For exactly 6 dB, the voltage ratio is approximately 1.995262, slightly below two. A ratio of exactly two corresponds to approximately 6.0206 dB, which is why treating 6 dB as a doubling is an approximation.
For exactly 20 dB, the ratio is ten. A 0.5 V RMS input would therefore correspond to 5 V RMS output if the amplifier operates linearly at that gain and load.
For −20 dB, the ratio is 0.1. The same 0.5 V RMS input would become 0.05 V RMS under that voltage-ratio model.
Do not apply the inverse relationship to an unrelated absolute level label without checking its reference. A gain in dB, a voltage level in dBu or dBV, and a power level in dBm answer different questions.
Keep Power Gain Separate from Voltage Gain
Power-ratio decibels use 10 log10(Pout/Pin). Voltage-magnitude decibels use 20 log10(Vout/Vin). They agree for the corresponding resistive power change only when the impedance conditions support that relationship.
At the same resistance, doubling voltage multiplies power by four. Then 20 log10(2) and 10 log10(4) both give approximately 6.0206 dB.
If the input and output resistive measurement boundaries differ, the power ratio also includes their resistance ratio:
Pout/Pin = (Vout/Vin)² × Rin/Rout
An amplifier can have a high-impedance signal input and a low-impedance power output. Its voltage-gain figure therefore does not automatically equal its electrical power gain in decibels.
For complex loads or general waveforms, real power needs the appropriate voltage/current relationship. The calculator is a voltage-ratio tool, not a complete real-power measurement or impedance-matching assessment.
Match Measurement Units and Signal Conditions
If input is 250 mV RMS and output is 5 V RMS, first convert 250 mV to 0.25 V. The gain is 5/0.25 = 20 V/V, again approximately 26.0206 dB.
Dividing five by 250 without converting units gives a ratio 1,000 times too small. That unit mistake changes the reported voltage gain by 60 dB, a large numerical error unrelated to the amplifier’s behaviour.
Use compatible RMS definitions, bandwidth, frequency, and timing. A peak input reading divided into an RMS output reading does not produce the intended RMS gain ratio.
Rane’s audio specifications note emphasizes the conditions needed to interpret audio measurements. Retain the signal frequency, output loading, level, channel, and control settings with a gain observation.
Check that neither measurement is dominated by noise, clipping, or an instrument response limitation. A correct logarithm cannot make incompatible measurements comparable.
Combine Cascaded Gains Without Mixing Ratios and dB
Linear voltage gains multiply when compatible stages operate in their linear range. Their decibel gains add.
For example, an illustrative stage with gain 10 followed by another with gain two has a total voltage ratio of 20. In decibels, 20 dB + 6.0206 dB = 26.0206 dB, matching the direct conversion.
Include loading effects where they are relevant. A stage’s unloaded voltage gain may differ from its gain when driving the next stage, so use the compatible loaded relationship rather than multiplying unrelated catalogue figures.
A gain-control position is not automatically a calibrated voltage ratio. A knob at halfway or a software fader at a particular position needs its actual control law or measurement before it can be translated into amplifier gain.
The total gain also does not establish total headroom. Any stage can reach its own input or output limit before another stage does. Keep gain structure and maximum permissible levels as separate system checks.
Interpret Zero Gain and Phase Correctly
An output of zero with positive input gives a zero linear magnitude ratio. Its logarithm has no finite decibel value; it is not 0 dB. The finite-decibel calculation therefore requires positive input and output magnitudes.
An inverting voltage stage can reverse polarity while preserving magnitude. A magnitude ratio of one still corresponds to 0 dB, while the polarity or frequency-dependent phase must be described separately.
Similarly, a delay can change phase without changing amplitude magnitude. The calculator’s voltage-gain result does not show time alignment, frequency response, or whether two loudspeakers sum as intended.
Record the gain as a magnitude relationship at the stated condition. Do not interpret a negative decibel number as proof of a polarity reversal or a positive number as proof of acoustic loudness.
Questions About Amplifier Gain in Decibels
Is a 3 dB voltage increase a doubling?
Three decibels corresponds to approximately 1.4125 times voltage. A doubling of voltage is approximately 6.0206 dB. A roughly 3 dB doubling applies to a power ratio under its stated conditions.
Is 0 dB the same as 0 dBu?
Zero dB gain is a unity ratio. Zero dBu is a voltage level relative to a specified reference. A gain figure and an absolute level cannot be substituted without identifying that reference and the input level.
Can the calculator show frequency response?
One input/output pair gives one magnitude ratio under its measurement condition. A frequency-response assessment requires a set of suitable measurements across frequency, with phase and other conditions retained where relevant.