Calculate a basic woofer Zobel network from an explicit voice-coil resistance-plus-inductance model: set the branch resistor equal to Re and the capacitor to Le/Re². Connect those two parts in series with each other, then place the complete RC branch across the driver and verify the actual impedance and crossover response.
Open the Zobel Network Calculator.
How to Calculate a Zobel Network for a Woofer
A basic driver Zobel is an impedance-compensation branch. It can offset the impedance rise of an ideal resistance Re in series with a lossless inductance Le, helping a crossover see the stated resistive load model.
The capacitor and resistor are in series within the compensation branch. That entire branch is in parallel with the driver. The resistor is not inserted in series with the woofer’s main signal path, and the capacitor is not connected alone across the amplifier.
The calculator reports the resistor in ohms or the capacitor in microfarads according to its output selector. Its model is deliberately specific: constant Re, lossless constant Le, and ideal RC components.
Real woofer inductance is lossy and frequency dependent, and the driver has a motional resonance and other behavior outside that simplified model. A two-part Zobel is therefore a starting approximation for a real driver, not a guarantee of perfectly flat impedance or acoustic response.
Use Voice-Coil DC Resistance Rather Than the Nominal Label
Re describes the resistance term in the chosen voice-coil model. It is distinct from the loudspeaker’s nominal impedance class, which describes its AC loading more broadly.
For example, a driver nominally labeled 8 ohms might have a documented Re of 6.4 ohms. That is not a contradiction, and it does not justify substituting 8 for 6.4 in a model explicitly defined around Re.
Use the actual parameter data or appropriate measurements. Account for measurement lead resistance and temperature where relevant. A warm coil can have a different resistance from a cold small-signal reference, which changes how closely a fixed compensation branch matches it.
Also verify which inductance value Le represents. A published inductance may be measured at a particular frequency or fitted to a more complicated model. Treating every such value as a constant lossless inductor over the whole audio band is an approximation.
Calculate and Convert the Two Components
For the exact ideal model, use Rz = Re. Calculate capacitance as Cz = Le/Re², with Le in henries and Cz in farads.
If Le is entered in millihenries and the result is wanted in microfarads, the direct conversion is CzµF = 1000 × Le_mH/Re².
Keep the square on resistance and the inductance in the numerator. Reversing that ratio does not produce capacitance. Dimensional analysis helps: a henry divided by ohms squared has units of farads.
The named quantities belong to the model and topology just defined. Other empirical compensation methods can use adjusted values for a real driver’s measured impedance. Those are different fitting choices rather than permission to add an unexplained multiplier to an exact ideal derivation.
Worked Example: Re of 6.4 Ohms and Le of 0.5 mH
Assume an illustrative woofer model consists of 6.4 ohms in series with 0.5 mH. Set the compensation resistor to 6.4 ohms.
Convert inductance to 0.0005 H, then calculate Cz = 0.0005/6.4², approximately 0.0000122070 F. The equivalent capacitance is approximately 12.207031 microfarads.
Enter 6.4 ohms and 0.5 mH in the calculator. Choose resistor output to confirm 6.4 ohms and capacitor output to confirm approximately 12.207031 microfarads. Record both values and their series connection within the parallel branch.
The frequency where the ideal coil reactance equals Re is Re/(2πLe), approximately 2,037.18 Hz. At that frequency, the driver-model impedance is 6.4 + j6.4 ohms.
The calculated RC branch has impedance 6.4 − j6.4 ohms at the same frequency. Their parallel combination is exactly 6.4 ohms in the ideal model, providing an independent check of the component equations and units.
Verify the Ideal Model Across Frequency
Write the driver impedance as Zd = R + sL and the branch as Zz = R + 1/(sC), where s represents complex frequency. With C = L/R², the two branch admittances add to 1/R.
The parallel total is therefore R at every frequency in this ideal model, not just at the characteristic frequency. The cancellation depends on the assumed lossless inductance and matched resistor.
For the illustrative model, the uncompensated impedance magnitude rises as follows while the ideal compensated total remains 6.4 ohms:
| Frequency | Uncompensated driver-model magnitude | Ideal compensated total |
|---|---|---|
| About 203.72 Hz | 6.432 ohms | 6.4 ohms, resistive |
| About 2,037.18 Hz | 9.051 ohms | 6.4 ohms, resistive |
| About 20,371.83 Hz | 64.319 ohms | 6.4 ohms, resistive |
This is a calculation table for the ideal RL model, not a measured woofer curve. Real drivers can depart from it substantially, particularly around resonance and where lossy inductance behavior becomes important.
W. Marshall Leach’s impedance-compensation paper explains why real lossy voice-coil inductance can require more complex compensation than one resistor and capacitor. The exact ideal result should therefore be kept separate from an empirical fit to an actual driver.
Check What the Network Does Not Correct
The simple RC branch does not cancel the driver’s low-frequency motional resonance peak. That feature requires a different model and, if compensation is desired, a different network.
It also does not automatically flatten acoustic output. The main purpose is changing electrical impedance presented to the crossover or source. Driver frequency response, baffle diffraction, enclosure alignment, and directivity remain separate acoustic properties.
An amplifier output-stability network is another application sometimes called a Zobel. Its purpose, location, and values can differ from the woofer voice-coil compensation discussed here. Do not copy a small amplifier-output RC network into a speaker crossover and assume it implements the calculated driver compensation.
Likewise, adding the branch does not certify an amplifier load. The compensation changes system impedance and current demand, so include it in the full network assessment rather than treating it as electrically invisible.
Calculate Resistor Dissipation from the Actual Signal
The branch resistor converts electrical energy to heat. Its dissipation depends on the voltage across the RC branch, capacitor reactance, signal spectrum, and time condition.
For a sinusoid, branch-current magnitude is V/sqrt(Rz² + Xc²), and resistor power is I²Rz. Use RMS voltage and current for average resistive dissipation.
At the example’s characteristic frequency, suppose an illustrative 10 V RMS appears across both parallel branches. The compensation resistor and capacitor reactance magnitudes are each 6.4 ohms, giving resistor dissipation of 10²/(2 × 6.4), or 7.8125 W.
The ideal RL driver model dissipates another 7.8125 W in its resistance term at that frequency, for 15.625 W total real input. These are hypothetical sine-wave conditions, not a recommended test level or a resistor rating.
Choose the physical resistor using its thermal, continuous, and transient specifications and actual mounting conditions. Check capacitor voltage and current suitability too. A nominal capacitance-and-ohm calculation does not supply those part ratings.
Fit Practical Values with Measured Impedance
Measure the driver’s impedance on an appropriate boundary and compare it with the simplified RL model through the region relevant to the crossover. A single nominal inductance value may not describe the measured rise accurately.
Evaluate practical resistor and capacitor values in a complete circuit simulation, including component losses. Recheck the driver-plus-branch impedance and the resulting crossover voltage response rather than assuming a nearby catalog pair preserves the exact ideal result.
Analog Devices’ audio applications handbook treats impedance compensation and crossover design as linked tasks. The compensation branch belongs in the crossover model before final filter behavior is assessed.
If the measured driver requires a more complex model, use appropriate fitting or network synthesis rather than extending the exact lossless equations beyond their assumptions. State the target frequency region and acceptable approximation when evaluating an actual design.
Verify the Completed Crossover and Load
Measure the completed system’s impedance and acoustic response after installing the branch. Check whether the intended crossover behavior improved and whether any new load demand affects amplifier suitability.
Retain the driver model, parameter source, measurement conditions, calculated values, installed parts, topology, dissipation assumptions, and final verification. A later driver replacement or crossover revision should prompt a new check because the original RC branch was chosen for a particular electrical model.