How to Calculate a Low Pass Filter for a Woofer

Calculate a first-order woofer low pass filter with a series inductor, using the combined load of any parallel woofers. When including inductor winding resistance, the calculator sets the corner 3.01 dB below the already reduced passband, so check both that frequency and the associated level loss.

Open the Low Pass Crossover Calculator.

How to Calculate a Low Pass Filter for a Woofer

A simple passive low-pass section places an inductor in series with the woofer load. Inductive reactance rises with frequency, so the voltage across the woofer model falls progressively at higher frequencies.

For an ideal lossless inductor and resistive load R, the corner is R/(2πL), with output approximately 0.7071 of input at that frequency. The electrical stopband approaches 6 dB per octave.

An actual inductor also has winding resistance. That reduces the low-frequency output and changes the response. The calculator includes a stated inductor DCR and defines its target frequency relative to that reduced passband.

This is an electrical model, not a complete acoustic crossover. The driver’s own response, impedance, enclosure, baffle, and interaction with another driver must be assessed before choosing final parts or operating limits.

Establish the Woofer Load Seen by the Inductor

For one woofer, start with its explicitly stated nominal resistive model. For N identical woofers connected in parallel after one shared inductor, use Rload = Rwoofer/N.

Two nominal 8-ohm woofers in parallel give a nominal 4-ohm load. A shared inductor feeding that pair is not the same circuit as a separate inductor feeding each individual woofer.

The calculator assumes identical parallel woofers, not arbitrary series-parallel branches. Use a whole count that matches the actual drawing and keep the amplifier-channel boundary clear.

If the drivers have different impedance curves or different branch components, the simple equal-load reduction is insufficient. Model their actual networks separately rather than substituting a convenient average resistance.

Check the amplifier’s supported load independently. Adding a winding resistance should not be relied on to make a prohibited speaker network acceptable, and nominal impedance does not capture every frequency-dependent demand.

Distinguish Winding Resistance from Reactance

Inductance L determines the reactive term XL = 2πfL. Winding DCR r is a separate series resistance that produces voltage drop and heat. They have different units and different roles.

A multimeter’s resistance measurement can estimate DCR, but it does not measure the coil’s inductance. An appropriate LCR or impedance measurement supplies different information under its stated test conditions.

The driver model R and winding resistance r together establish the series current. Output is taken only across R, so part of the applied voltage appears across the winding resistance even at low frequency.

The voltage transfer magnitude is R/sqrt[(R + r)² + (2πfL)²]. This equation shows why an inductor with the correct nominal mH but a different DCR can change both level and damping in an existing design.

Use the Calculator’s Relative-Passband Corner

At very low frequency, the model’s output ratio approaches R/(R + r). That is its passband reference, which is below one when r is nonzero.

The frequency where output is another 3.01 dB below that reduced passband is (R + r)/(2πL). Solving for inductance gives L = (R + r)/(2πfc).

The calculator substitutes Rwoofer/N for R and returns L in millihenries. Enter the assumed inductor DCR in ohms; do not enter the driver’s voice-coil resistance in that field.

When r is zero, the formula reduces to the usual lossless first-order equation. When r is nonzero, the output at fc is lower than −3.01 dB relative to the original input because the passband loss is already present.

Keep that frequency definition with the result. A calculation referenced to input voltage rather than the reduced passband can use a different criterion and should not be compared without clarifying the reference.

Worked Example: Two 8-Ohm Woofers and an 800 Hz Corner

Assume an illustrative pair of identical nominal 8-ohm woofer models is connected in parallel after a shared inductor. The intended relative-passband corner is 800 Hz, and provisional inductor DCR is 0.3 ohm.

The combined resistive load is 8/2 = 4 ohms. Required inductance is (4 + 0.3)/(2π × 800) henries, approximately 0.855458 mH.

Enter 8 ohms per woofer, 800 Hz, two parallel woofers, and 0.3-ohm inductor DCR. The calculator should return approximately 0.855 mH with its displayed rounding.

Without winding resistance, the corresponding ideal value would be approximately 0.795775 mH. The larger value in the DCR-inclusive calculation maintains the stated corner relative to the reduced passband; it does not remove the winding loss.

Passband voltage ratio is 4/4.3, approximately 0.93023, or −0.628 dB relative to input. At 800 Hz, the model is another −3.01 dB below that passband, about −3.64 dB relative to input.

These are illustrative design assumptions rather than recommended values for unspecified woofers. Their actual upper response and intended acoustic crossover still determine whether the circuit is suitable.

Compare the Ideal Response Around the Corner

Relative to the model’s reduced passband, the normalized low-pass magnitude remains 1/sqrt(1 + (f/fc)²).

Frequency with an 800 Hz relative corner Magnitude relative to reduced passband Relative attenuation Include passband loss for input reference
400 Hz 0.8944 −0.97 dB Add the example’s −0.628 dB
800 Hz 0.7071 −3.01 dB Add the example’s −0.628 dB
1,600 Hz 0.4472 −6.99 dB Add the example’s −0.628 dB
3,200 Hz 0.2425 −12.30 dB Add the example’s −0.628 dB

The curve approaches a 6 dB-per-octave high-frequency decline. A woofer continues receiving some higher-frequency input above the corner, so a simple inductor may not sufficiently suppress breakup or another unwanted response feature.

Georgia State University’s crossover-network reference illustrates the series-inductor low-pass role. The complete driver behavior determines whether that basic role is enough for a particular design.

Check Practical Inductor Values and DCR Together

An inductor’s DCR depends on construction, wire, and value. The provisional resistance used in the calculation may not match the part eventually selected, so the design can require iteration.

For illustration, suppose an available part is 0.82 mH with 0.25-ohm DCR. With the same 4-ohm load, its relative-passband corner is 4.25/(2π × 0.00082), approximately 825 Hz.

That result is close to the target but different from the original 0.855458 mH and 0.3-ohm assumptions. Evaluate the actual pair of properties rather than matching only the millihenry value.

Jantzen Audio’s coil catalog lists inductance, DCR, wire size, and dimensions separately. Use corresponding manufacturer data to select and model a physical component, including tolerance and relevant current behavior.

Do not treat lower DCR as an automatic drop-in improvement. If an existing crossover was designed around a particular winding resistance, changing it can alter level and response even at the same nominal inductance.

Estimate Winding Heating Under a Defined Condition

Winding heat is I²r for the relevant RMS current. In the illustrative low-frequency resistive limit, a hypothetical 20 V RMS across the entire 4.3-ohm circuit gives approximately 4.651 A RMS.

The load receives approximately 86.53 W, while the winding resistance dissipates approximately 6.49 W. At the 800 Hz relative corner, current magnitude falls by the square root of two, so those resistive powers halve in this model.

These are calculation examples, not recommended test levels or component ratings. Select the inductor using its thermal and current properties, including core behavior if applicable, and review the actual signal conditions.

An air-core coil avoids magnetic-core saturation but still has resistance, heating, and physical-size requirements. A magnetic-core coil has additional current-dependent behavior to assess from appropriate data.

Verify the Acoustic Low-Pass and Crossover Sum

Use measured complex driver impedance and response on the intended baffle for final modeling. Include winding resistance, other crossover parts, level-matching networks, and relevant source resistance.

Measure the filtered woofer and adjacent driver separately, then together with a consistent timing reference. Check transition-band magnitude and phase, useful listening angles, and system impedance.

Keep the parallel-driver count, load assumption, corner reference, provisional and installed inductance, DCR, component data, and verification results together. This preserves the distinction between a correctly calculated electrical low-pass and the complete loudspeaker response it is intended to create.

Table of contents